Products

  • GDVLF-80S VLF AC Hipot Test Set

    GDVLF-80S VLF AC Hipot Test Set

    Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages.

  • GDYT-10/100 Partial Discharge Testing System

    GDYT-10/100 Partial Discharge Testing System

    GDYT-10/100 Partial Discharge Test System is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It is widely used in electrical manufacturing, power operation departments, research institutes and universities.

  • GDYD-55D AC/DC Hipot Test Set

    GDYD-55D AC/DC Hipot Test Set

    GDYD series AC/DC Hipot Test Set is composed of manual control unit and dry testing transformer (HV unit) which output AC voltage smoothly. When adding a HV diode, it can output DC voltage. Meanwhile, it has many monitoring and protection functions. 

  • GDHX-9500B Phase Detector

    GDHX-9500B Phase Detector

    GDHX-9500B Phase Detector is mainly used in electric power lines, phase and phase sequence calibration in substation, with main functions including electrical inspection,  phase calibration and phase sequence measurement. It uses double shielding and brand new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations.

  • GDCY-20P Impulse Voltage Test System

    GDCY-20P Impulse Voltage Test System

    The equipment is according to impulse voltage testing requirement of the low-voltage power distribution system SPD II product and solar battery, enable to generate impulse voltage (1.2/50μs), is used for grade III test and limiting voltage test of SPD and components. It is also used for impulse current test and residual voltage test of the MOV valve plate, unit and surge protective device(SPD), or used in other scientific research experiments.

    The equipment uses touch screen and PLC control technology, and the main performance meets the needs of domestic and foreign SPD products and their components for various combination wave testing.

  • GDOT-3B 100kV Three Cups Insulation Oil Breakdown Voltage (BDV) Tester

    GDOT-3B 100kV Three Cups Insulation Oil Breakdown Voltage (BDV) Tester

    In the power system and factories, mines, enterprises have a large number of electrical equipment, its internal insulation are oil-filled insulation. The dielectric strength test of the insulating oil is a routine test must be measured.

    In order to adapt to the needs of the rapid development of the power industry, the new version GDOT-3B Insulation oil BDV tester increase the standards and methods of selection and other content, simplify the user’s operation, to facilitate the application of the user for different conditions of use. This product is based on the new test protocol DL/T 596-2005 and the corresponding national standard GB/T 507-2002 and DL/T 429.9-91 design and manufacture, the use of micro-single-chip computer control, electromechanical integration of all automation, high measurement accuracy, greatly improving the efficiency of the work, but also greatly reduces the staff’s labor intensity.

     

     

  • GDJB-1200A Six Phase Relay Protection Test Set

    GDJB-1200A Six Phase Relay Protection Test Set

    GDJB-1200A Six Phase Relay Protection Microcomputer Test Device plays a key role in operating electricity power systems reliably and safely. It is the testing device used in professional field of microcomputer protection, relay protection, excitation measurement, fault recorder.

     

  • GDBT-10000kVA/36kV Transformer Test System

    GDBT-10000kVA/36kV Transformer Test System

    GDBT-10000kVA/36kV is mainly to make no-load and load test, power frequency withstand voltage test, induction withstand voltage test, temperature rising test, DC resistance test and ratio test for 36kV, 10000kVA and below distribution transformers.

  • GDYD-1210D   AC Hipot Test Set

    GDYD-1210D AC Hipot Test Set

    GDYD series AC/DC Hipot Test Set is composed of manual control unit and dry testing transformer (HV unit) which output AC voltage smoothly. When adding a HV diode, it can output DC voltage. Meanwhile, it has many monitoring and protection functions. 

  • GDSF-411WPD 3-in-1 SF6 Gas Analyzer(with pump)

    GDSF-411WPD 3-in-1 SF6 Gas Analyzer(with pump)

    GDSF-411WPD is an ideal instrument when it is necessary to test water content, purity, and decomposition products of SF6 gas. The core component of dew point test is DRYCAP® series sensors produced by Finland Vaisala company. The infrared principle SF6 gas purity testing sensor manufactured by European Sensor Company is used to test the purity of SF6 gas. The electrochemical sensor manufactured by Mombabo Company in Switzerland is used as the sensing element for the test of SF6 gas decomposition products. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of 3-in-1 gas analyzer.

  • GDTF-2700kVA/900kV AC Resonant Test System

    GDTF-2700kVA/900kV AC Resonant Test System

    GDTF-2700kVA/900kV is specially designed for AC withstand voltage test for 500kV or below switch, GIS, instrument transformers and neutral point of main transformers.The system includes Variable frequency power supply, exciting transformer, reactor, and capacitive voltage divider.

  • GDUVI-41 Partial Discharge UV Imager

    GDUVI-41 Partial Discharge UV Imager

    GDUVI-41 UV imager adopts ergonomic design and key operation, which is very suitable for daily maintenance of various high-voltage electrical equipment. The instrument adopts solar-blind technology to simultaneously image the visible light and ultraviolet light paths, and realizes the location of the ultraviolet light-emitting position through the real-time synchronous fusion of the two images, which can be detected around the clock. The video display can display the ultraviolet video and the visible light video separately, or the superimposed composite video, which can count the ultraviolet light spots in the selected range and provide the measurement data.

    The instrument is small, light, powerful, and has good controllability. It can help you find and eliminate equipment failures in advance and prevent accidents. It is the most ideal common preventive maintenance testing tool in various industries such as power, electrical, railway, and factories.

     

123456 Next > >> Page 1 / 19

Send your message to us:

Write your message here and send it to us